Undercounter chillers are the perfect cold storage solution, especially for commercial kitchens dealing with small footprints. But when they stop working correctly, like when the defrost fails, things get chaotic fast. Why should you care so much? In fact, a recent industry report states that defrost failure causes nearly 28% of all service calls in foodservice operations! That's huge! That’s why learning a bit about proper defrost troubleshooting is so important; it drastically cuts down on expensive breakdown time and unnecessary repair costs. Let's dive in and fix this!
Before you troubleshoot, it helps to know the logic behind the system.
Most commercial undercounter chillers use one of three defrost types:
The defrost cycle keeps the evaporator coil free of ice, allowing cool air to circulate evenly. Without it, ice creates a barrier that traps cold air and forces the compressor to work overtime, leading to energy waste and early failure.
Here’s a quick breakdown of the most frequent culprits behind a non-defrosting unit, from technical to environmental factors.
| Cause | Explanation | How to Check |
|---|---|---|
| Defrost Timer Failure | Timer stuck or not triggering cycle. | Listen for clicks or use a multimeter to test continuity. |
| Faulty Defrost Heater | Heating element burned out or disconnected. | Visual check for burn marks or continuity test. |
| Defrost Thermostat (Termination Switch) | Stuck open, preventing heater activation. | Test resistance under cold and warm conditions. |
| Blocked Airflow | Ice buildup or dirty fans restricting circulation. | Inspect coils and fan blades for frost or debris. |
| Faulty Temperature Sensor (Thermistor) | Sensor misreads coil temperature. | Compare actual coil temp with sensor readings. |
| Improper Door Sealing | Warm air infiltrates, causing excess frost. | Check door gasket for gaps or cracks. |
Pro Tip: If your chiller forms thick frost within 12–24 hours after cleaning, chances are high your defrost heater or timer has failed.
Controls when and how long the system defrosts. Usually programmed for 15–30 minutes every 6 hours. A worn-out timer may freeze in one position, keeping your system “stuck in cooling.”
Located beneath or around the evaporator coil. Uses electrical resistance to melt accumulated frost. In an undercounter unit, the wattage typically ranges from 200–600W, depending on size.
Terminates the defrost cycle once the coil temperature reaches around 10°C. A faulty thermostat leads to either incomplete or continuous defrosting.
Collects and disposes of melted frost water. Clogging here is one of the most overlooked maintenance issues.
Follow these tested diagnostic steps to pinpoint and fix the issue efficiently.
If your model uses a thermistor, compare its resistance reading with manufacturer's specs. For most undercounter chillers:
Out-of-range readings indicate the sensor should be replaced.
| Action | Frequency | Benefit |
|---|---|---|
| Check door gaskets | Monthly | Maintains air seal |
| Defrost manually (manual units) | Weekly | Resets coil efficiency |
| Clean evaporator coils | Every 2–3 months | Prevents frost accumulation |
| Inspect drain line | Monthly | Prevents clog and ice block |
| Schedule technician inspection | Bi-annually | Extends compressor lifespan |
If the defrost issue recurs within days or the compressor overheats, stop DIY repairs. Persistent frost formation could indicate:
A licensed commercial refrigeration technician can perform amp draw tests and refrigerant pressure checks that aren’t safe for untrained personnel.
Q1: How often should an undercounter chiller defrost?
Every 6–8 hours under normal use. Frequency may vary depending on humidity and door openings.
Q2: Can I defrost a chiller manually?
Yes. Turn it off, remove food, and leave the door open for 3–4 hours. Clean up meltwater afterward.
Q3: Why does ice return right after defrosting?
Likely due to a broken door seal or humidity infiltration. Check gaskets and drain.
Q4: How do I know if my defrost timer is bad?
If the compressor runs continuously and no heat cycle activates, the timer is stuck.
Q5: Can a defrost issue increase electricity use?
Absolutely. A frozen evaporator coil can make your compressor run 40–60% longer.
Q6: Should I replace or repair my chiller?
If the repair cost exceeds 40% of the replacement price or the unit is over 8 years old, replacement is more cost-effective.
Since Shinelong was established in Guangzhou in 2008, we have made great strides in the fields of commercial kitchen planning and kitchen equipment manufacturing.
IF YOU HAVE ANY QUESTION,PLEASE CONTACT US.
WhatsApp: +8618902337180
WeChat: +8618924185248
Telephone: +8618924185248
Fax: +86 20 34709972
Email: info@chinashinelong.com
After-Sales Contact
Telephone: +8618998818517
Email: service@chinashinelong.com
Add: No. 1 Headquarters Center, Tian An Hi-tech Ecological Park, Panyu Avenue, Guangzhou, China.